Robotics Sensors and Actuators

117403
Back to Robotics Sensors and Actuators

Module 3: Force and Torque measurment

  1. Q1(b). Load cells are commonly used as: (i) Position sensors (ii) Velocity sensors (iii) Force sensors (iv) Temperature sensors20252m

    Module 3: Force and Torque measurment

    Load cells are commonly used as:
    (i) Position sensors
    (ii) Velocity sensors
    (iii) Force sensors
    (iv) Temperature sensors

    View this question on its own page →
    Worked Solution

    Correct answer: (iii) Force sensors. A load cell converts applied force or weight into an electrical output, commonly using strain gauges whose resistance changes with deformation.

  2. Q4a. What Is a Strain Gauge Sensor and How Does It Work? Write its Advantages, Disadvantages & Applications.20247m

    Module 3: Force and Torque measurment

    What Is a Strain Gauge Sensor and How Does It Work? Write its Advantages, Disadvantages & Applications.

    View this question on its own page →
    Worked Solution

    Answer

    1. What is Strain Gauge?

    Resistive sensor measuring strain ϵ=ΔL/L\epsilon = \Delta L/L via resistance change. Bonded to structure, deforms with it.

    2. How It Works

    Resistance R=ρL/AR=\rho L/A. Strained → LL ↑, AA ↓ → RR changes: ΔR/R=GF⋅ϵ\Delta R/R = G_F \cdot \epsilon, GFG_F gauge factor (~2). Wheatstone bridge measures ΔR\Delta R: Vo=Vs⋅(ΔR/4R)V_o = V_s \cdot (\Delta R/4R) for quarter bridge.

    3. Advantages

    • High sensitivity for force/pressure/weight.
    • Small, cheap, static + dynamic.
    • Easy bridge interfacing.

    4. Disadvantages

    • Temperature drift (needs compensation).
    • Small signal (mV) needs amplification.
    • Bonding sensitive, hysteresis.
    • Nonlinear for large strain.

    5. Applications

    • Load cells, weighing scales.
    • Robot force sensing, torque measurement.
    • Structural health monitoring.
    • Pressure diaphragms.

    Final Answer

    Strain gauge = ΔR/R=GFϵ\Delta R/R=G_F\epsilon via Wheatstone bridge; advantages high sensitivity for force, used in load cells/robot force, disadvantages temperature drift and small signal.

  3. Q4b. What is a Ultrasonic sensor? How it Works? Types, Advantages, Disadvantages & Applications.20247m

    Module 3: Force and Torque measurment

    What is a Ultrasonic sensor? How it Works? Types, Advantages, Disadvantages & Applications.

    View this question on its own page →
    Worked Solution

    Answer

    1. What is Ultrasonic Sensor?

    Non-contact distance/proximity sensor using ultrasound (40kHz) time-of-flight.

    2. How It Works

    Transmitter emits chirp → reflects off object → receiver measures TOF TT, distance d=c⋅T/2d = c\cdot T/2, c≈343c≈343m/s air.

    3. Types

    Type Principle
    Transceiver (single) Same element TX/RX
    Separate TX/RX Two elements
    Analog Continuous dd voltage
    Digital Threshold binary

    4. Advantages

    • Works on any material/color, transparent.
    • Range 2cm–4m, low cost.
    • Not affected by light.

    5. Disadvantages

    • Slow (sound speed), 40ms per measurement.
    • Beam spread (30°), poor for narrow.
    • Temperature affects cc, soft materials absorb.
    • Minimum dead zone ~2cm.

    6. Applications

    • Robot obstacle avoidance, parking.
    • Level sensing (tank).
    • Medical imaging, non-destructive testing.

    Final Answer

    Ultrasonic = d=cT/2d=cT/2 TOF, types transceiver/separate, advantages material-independent range, used for robot navigation and level sensing but slow and beam-wide.

  4. Q5(a). Explain force sensors. Discuss their types, applications, and limitations.20257m

    Module 3: Force and Torque measurment

    Explain force sensors. Discuss their types, applications, and limitations.

    View this question on its own page →
    Worked Solution

    Force sensors: Measure applied force, often using elastic deformation. Types include strain-gauge load cells (resistance changes with strain), piezoelectric sensors (charge under dynamic force), capacitive sensors (gap/area change), and optical force sensors. A strain-gauge bridge output is amplified and calibrated to force. Applications: robot grippers, force control, assembly, polishing, tactile interaction, and medical rehabilitation. Advantages include measurable feedback and safer compliant interaction. Limitations: calibration/drift, temperature sensitivity, hysteresis, overload damage, cross-axis sensitivity, and noise. Piezoelectric types are excellent for dynamic forces but generally not static force measurement without specialised circuitry.

  5. Q5(b). Explain torque sensors along with types and applications.20257m

    Module 3: Force and Torque measurment

    Explain torque sensors along with types and applications.

    View this question on its own page →
    Worked Solution

    Torque sensors: Measure rotational moment, τ = F×r for perpendicular force and lever arm. Strain-gauge torque sensors measure torsional strain on a shaft, often using gauges at ±45° in a bridge; magnetoelastic, optical, and piezoelectric approaches are also used. Rotary sensors may transmit signals via slip rings or wireless telemetry. Applications include robot joint torque feedback, motor/gear testing, tightening tools, and force-controlled manipulation. Important specifications are range, accuracy, resolution, bandwidth, overload capacity, temperature stability, and rotational signal transfer. Torque feedback improves control and helps detect collisions or excessive contact forces.

  6. Q6a. What is a Torque sensor? How it Works? Types, Advantages, Disadvantages & Applications.20247m

    Module 3: Force and Torque measurment

    What is a Torque sensor? How it Works? Types, Advantages, Disadvantages & Applications.

    View this question on its own page →
    Worked Solution

    Answer

    1. What is Torque Sensor?

    Sensor measuring twisting moment τ=r×F\tau = r \times F (Nm) on shaft.

    2. How It Works

    Twist angle θ=TL/(GJ)\theta = TL/(GJ) or strain on shaft. Transduction via strain gauges at 45° (max shear) on shaft, Wheatstone bridge measures ΔR\Delta R.

    • Reaction: Static mount measures reaction torque.
    • Rotary: Slip rings/telemetry for rotating shaft.

    3. Types

    Type Principle
    Strain gauge ΔR/R\Delta R/R on shaft
    Magnetoelastic Permeability change
    SAW Frequency shift
    Optical Twist angle via encoder

    4. Advantages

    • Control joint effort, assembly.
    • Overload protection.
    • Small, high sensitivity.

    5. Disadvantages

    • Temperature drift, needs calibration.
    • Slip ring wear for rotary.
    • Cross-sensitive to bending.

    6. Applications

    • Robot joint torque control, grinding, screwing.
    • Automotive engine, steering.
    • Prosthetics.

    Final Answer

    Torque = strain on shaft at 45° via bridge; types strain gauge/magnetoelastic; used for robot joint control with high sensitivity but temperature drift.