If an AM transmitter operates at 1000 kHz carrier frequency with a total power of 10 kW and modulation index of 0.8, determine the power in the carrier and sidebands.

Worked SolutionAI Assisted

Answer

Given Pt=10P_t=10kW μ=0.8\mu=0.8: Pt=Pc(1+μ2/2)P_t=P_c(1+\mu^2/2) → Pc=10/1.32=7.58P_c=10/1.32=7.58kW, PSB=2.42P_{SB}=2.42kW total, each 1.21kW. Efficiency μ2/(2+μ2)=24.2%\mu^2/(2+\mu^2)=24.2\%.